Avaya S8700 Maintenance Manual page 1319

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

DS1-BD (DS1 Interface Circuit Pack)
NPE Connection Audit Test (#50):
The system sends a message to the on-board microprocessor to update the
network connectivity translation for all the Network Processing Elements (NPEs)
on the circuit pack.
Table 8-241. Test #50 NPE Connection Audit Test
Error
Test
Code
Result
Description / Recommendation
None,
ABORT
System resources required for this test are not available.
2100
1019
ABORT
Test already in progress.
FAIL
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
PASS
The circuit pack's NPEs have been updated with their translation.
0
NO
The test could not relate the internal ID to the port (no board).
BOARD
This could be due to incorrect translations, no board is inserted, an incorrect
board is inserted, or an insane board is inserted.
1. Verify that the board's translations are correct. Use the add ds1 UUCSS
2. If board was already administered correctly, check the error log to
3. Issue the busyout board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
555-233-143
command to administer the DS1 interface if it is not already administered.
determine whether the board is hyperactive. If so, the board was shut
down. Reseating the board will re-initialize it.
This should re-establish the linkage between the internal ID and the port.
Continued on next page
Issue 1 May 2002
8-597

Advertisement

Table of Contents
loading