Avaya S8700 Maintenance Manual page 739

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

ADX8D-PT (AUDIX Digital Port)
Error Log Entries and Test to Clear Values
Table 8-6. EMBEDDED AUDIX Digital Port Error Log Entries
Error
Aux
Type
Data
Associated Test
1
0
0
Any
1 (a)
40987
None
1 (b)
1 to
None
20
15 (c)
Any
None
18 (d)
0
busyout port
UUCSSpp
23 (e)
0
None
130 (f)
None
257 (g)
40971
None
513 (h)
Any
None
1537 (i)
40968
None
1793
Voice & Ctrl. Local
Loop test (#13)
2049
NPE Crosstalk test (#9)
2305 (j)
40967
None
3840 (k)
40965
None
3840 (l)
41029
None
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test's description, and follow its recommended procedures.
2.
Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the set options
command.
Notes:
a. The user may experience a noisy port or link, due to an off-board problem
that is detected by the port circuit. If so, replace the circuit pack (see
caution at the beginning of this section). Once the problem is resolved, the
alarm is retired after a predetermined time.
b. At least 15 off-board problems have been detected with the link to the voice
port. When an error with the link is detected, an on-board counter is
incremented. Also see Note (a).
c. This is an internal type error that occurs when an audit request fails.
555-233-143
Alarm
On/Off
Level
Board
Test to Clear Value
Any
Any
test port UUCSSpp sh r 1
WARNING
OFF
WARNING
OFF
WARNING
OFF
release port UUCSSpp
WARNING
OFF
WARNING
ON
test port UUCSSpp sh
WARNING
OFF
MINOR
ON
test port UUCSSpp l r 3
WARNING
2
MINOR
ON
test port UUCSSpp l r 3
WARNING
2
Issue 1 May 2002
8-17

Advertisement

Table of Contents
loading

Table of Contents