Avaya S8700 Maintenance Manual page 876

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
Table 8-58. Test #626 Signaling Link Status Test
Error
Test
Code
Result
Description / Recommendation
1139
ABORT
The EPN's packet bus is out-of-service.
1. Follow the repair procedures for the packet bus.
2. After completing step 1, execute the test port long UUCSSpp command
1141
ABORT
The PKT-CTRL is out-of-service.
1. Refer to PKT-CTRL maintenance documentation.
1187
ABORT
The circuit pack, port, or station may have been busied out.
1. Look in the Error Log for Error Type 18 (busied out) for ASAI-BD, ASAI-PT,
2. If this Error Type is present for ASAI-EPT only, then use the release
3. If this Error Type is present for ASAI-PT and ASAI-EPT, then use the
4. If this Error Type is present for ASAI-BD, ASAI-PT, and ASAI-EPT, then
2012
ABORT
Internal system error
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1113
FAIL
The signaling link is not "bound" to the adjunct. For ASAI adjuncts this error
indicates that the link is disconnected at Layer 2. Since the signaling link
associated with the endpoint has been identified by administration, the link is
only "unbound" from the endpoint when it is disconnected.
1. Execute the status bri-port UUCSSpp command and see
PASS
The signaling link is connected at Layer 2 and "bound" to the ASAI adjunct.
8-154
Issue 1 May 2002
and review the results of the BRI Port Local LAN Looparound test (#618) to
verify the repair.
or ASAI-EPT.
station command and run the test again.
release port command and run the test again.
use the release board command and run the test again.
(ISDN-BRI Port), ABRI-PORT (ASAI ISDN-BRI
''BRI-PORT
Port)''.
Continued on next page