Inads (Inads Link) - Avaya S8700 Maintenance Manual

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

INADS (INADS Link)

INADS (INADS Link)
MO's Name (in
Alarm Log)
INADS
The INADS Link MO represents the software and communications link used by
the switch to call an alarm receiver. The purpose of the INADS Link MO is to:
Check the communications link between the system and the alarm receiver
Verify that the alarm notification process works correctly
To verify that alarms will be reported to the alarm receiver, either a centralized
technician can remotely test the process, or an on-site technician can test the
connection either during an installation or a subsequent service call.
Although the INADS Link MO never alarms, its errors are logged, and these errors
are only logged by issuing the test inads-link command.
Error Log Entries and Test to Clear Values
The Hardware Error Log entries are described as part of the following INADS Link
test description.
System Technician-Demanded Tests:
Descriptions and Error Codes
The test inads-link command is different from other test commands in that the:
Command does not have a long or short option
Resulting test does not have an associated test number.
When a user issues the test inads-link command, the system immediately
returns either the "Command successfully completed" or "Command failed"
message.
555-233-143
Initial SAT Command to
Alarm Level
Run
none
test inads-link
Full Name of MO
INADS Link
Issue 1 May 2002
8-925

Advertisement

Table of Contents
loading