DID-TRK (Direct Inward Dial Trunk)
Table 8-210. Test #33 Loop-Around and Conference Circuit Test — Continued
Error
Test
Code
Result
Description / Recommendation
1004
ABORT
The port was seized by a valid call during the test.
1. Enter display port UUCSSpp to determine the station extension,
2. Retry the command at 1-minute intervals up to 5 times.
1018
ABORT
Test disabled via administration. Verify that the
field on the Trunk Group Form is set to
change trunk-group x command (x is the trunk group number). Then
change the entry in the
2000
ABORT
Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABORT
System resources required to run this test are not available. This may be due
to the port being seized.
1. This abort code is usually associated with tone-clock (TONE-BD,
2. Retry the command at 1-minute intervals up to 5 times.
555-233-143
attendant number, or trunk group/member number of the port. Use
status station, status attendant, or status trunk to determine the
service state of the port. If the port is in use, wait until it is idle before
testing. Attendants are always in use (off-hook), if the handset is plugged
in and the port is not busied out.
Maintenance Tests?
TONE-PT, and TDM-CLK) resources. Clear any tone errors in the error
log.
Maintenance Tests?
. To enable the test, issue the
n
field to y.
Continued on next page