Avaya S8700 Maintenance Manual page 1437

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

DS1 CONV-BD
Board Options Audit (#795)
This test is nondestructive.
This test sends the administered circuit pack options to the DS1 CONV circuit
pack. Options are sent to both DS1 CONV circuit packs at the same time to
prevent any transitional mismatch of options.
The following data is sent to the TN574 DS1 CONV circuit pack:
system-reliability configuration
master and slave endpoints for framing (determined by the relative position
of the circuit pack to the media server)
facility mask (whether each facility is installed)
clock reference mask (whether:
— each facility can be used as a clock-reference source
— the board is being used as a network-timing source)
packet compatible mask (whether each facility is packet compatible)
facility information for line coding, framing mode, and line compensation
The following data is sent to the TN1654 DS1 CONV circuit pack:
system-reliability configuration
master and slave endpoints for framing (determined by the relative position
of the circuit pack to the media server)
facility mask (whether each facility is installed)
idle code
CRC-enabled/-disabled flag (sent in E1 mode only)
facility information for line coding and line compensation (sent in T1 mode
only).
555-233-143
Issue 1 May 2002
8-715