CO-TRK (Analog CO Trunk)
Table 8-186. Test #3 CO Demand Diagnostic Test — Continued
Error
Test
Code
Result
Description / Recommendation
0
NO
The test could not relate the internal ID to the port (no board).
BOARD
1. Verify that the board's translations are correct. Translate the board, if
2. Issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board command. This should re-establish the linkage
555-233-143
necessary.
between the internal ID and the port.
Continued on next page