Maintenance-Object Repair Procedures
Port Audit Update Test (#36)
This test sends updates of the DID port translation for every port on the circuit
pack that has been translated. The update is non-disruptive and guards against
possible corruption of translation data contained on the circuit pack. No response
message is expected from the circuit pack once it receives translation updates.
The port translation data includes:
Wink or immediate start trunk
Dial tone or rotary dialing trunk
Rotary dialing inter-digit timing
Network balance R/RC
Disconnect timing
Table 8-212. Test #36 Port Audit Update Test
Error
Test
Code
Result
Description / Recommendation
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1006
ABORT
The port is out of service, perhaps busied out.
1. Use display port UUCSSpp to determine the trunk group/member number
2. If the port status is in service and idle, then retry the command at 1-minute
2100
ABORT
Could not allocate the necessary system resources to run the test.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
8-528
Issue 1 May 2002
of the port. Use status trunk to determine the service state of the port. If
the port is out of service, wait until the port is in service and idle before
testing.
intervals up to 5 times.