Maintenance-Object Repair Procedures
Table 8-74. Test #258 ISDN Test Call — Continued
Error
Test
Code
Result
Description / Recommendation
1020
ABORT
TN230x circuit-pack problem
1. See the
1024
ABORT
Maintenance/Test digital port active
1. Wait until amber and green LEDs on the Maintenance/Test circuit pack are
2. Rerun the test.
3. If the problem persists, see
1113
ABORT
Signaling link failed
1. Check the results of Test #255 (Signaling Link State Check test).
1116
ABORT
Switch could not change the service state
1. See if calls are active. Run status trunk grp#/mbr#.
2. If a call is active, proceed as for Error Code 1119.
1117
ABORT
ISDN service message outstanding
1. Wait 2 minutes. Then try again.
1118
ABORT
Far-end not administered
1. Check the administration of the far end of the ATM trunk. Run status
2. Try the test again.
1119
ABORT
Test call aborted, normal call attempted
1. Wait for the call to finish normally, or drop it by running busyout trunk
2. When the trunk is idle, retry the test.
1120
ABORT
Trunk OUT-OF-SERVICE/FAR-END
1. Try to change the service state via Test #256 (Service State Audit test).
2. Try the test again.
1122
ABORT
No test-line number for the far-end switch
1. Check the Trunk Group Administration form.
1123
ABORT
No Feature Access Code administration for this Facility test
1. Check the Dial Plan and Feature Administration forms.
8-180
Issue 1 May 2002
''ATM-INTF (TN2305/6)''
OFF.
MO.
If not, check the Error and Alarm Logs and see
Emulation Service Circuit
trunk grp#/mbr#.
grp#/mbr#.
MO.
''M/T-DIG (Maintenance/Test Digital Port)''
''ATM-TRK (Circuit
Pack)''.
Continued on next page