Avaya S8700 Maintenance Manual page 1578

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
Table 8-328. Test #759 Configuration Audit — Continued
Error
Test
Code
Result
Description / Recommendation
215
FAIL
The SNI circuit pack (Endpoint 2) cannot communicate with the equipped SNI
in slot 15. (The list fiber-link command displays a fiber link's endpoints.)
1. Perform the
2. If the SNI being tested has SNI-PEER Error Type 2561, replace the SNI
3. If the SNI being tested still has SNI-PEER Error Type 2561, replace the
216
FAIL
The SNI circuit pack (Endpoint 2) cannot communicate with the equipped SNI
in slot 16. (The list fiber-link command displays a fiber link's endpoints.)
1. Perform the
2. If the SNI being tested has SNI-PEER Error Type 2817, replace the SNI
3. If the SNI being tested still has SNI-PEER Error Type 2817, replace the
217
FAIL
The SNI circuit pack (Endpoint 2) cannot communicate with the equipped SNI
in slot 17. (The list fiber-link command displays a fiber link's endpoints.)
1. Perform the
2. If the SNI being tested has SNI-PEER Error Type 3073, replace the SNI
3. If the SNI being tested still has SNI-PEER Error Type 3073, replace the
8-856
Issue 1 May 2002
''Fault Isolation for Fiber Links'' on page
resolve multiple SNI-PEER errors.
being tested. (Replacing an SNI may be service interrupting. Refer to the
SNI-BD section for the procedure to replace an SNI.) To view SNI-PEER
errors, use the display errors command with category PNC-PEER. Retry
the command.
SNI in slot 15.
''Fault Isolation for Fiber Links'' on page
resolve multiple SNI-PEER errors.
being tested. (Replacing an SNI may be service interrupting. Refer to the
SNI-BD section for the procedure to replace an SNI.) To view SNI-PEER
errors, use the display errors command with category PNC-PEER. Retry
the command.
SNI in slot 16.
''Fault Isolation for Fiber Links'' on page
resolve multiple SNI-PEER errors.
being tested. (Replacing an SNI may be service interrupting. Refer to the
SNI-BD section for the procedure to replace an SNI.) To view SNI-PEER
errors, use the display errors command with category PNC-PEER. Retry
the command.
SNI in slot 17.
4-19. This should
4-19. This should
4-19. This should
Continued on next page
555-233-143

Advertisement

Table of Contents
loading

Table of Contents