Maintenance-Object Repair Procedures
This section covers the maintenance documentation for ISDN-BRI ports. Some of
the results of maintenance testing of ISDN-BRI ports may be affected by the
health of the ISDN-BRI Line circuit pack (BRI-BD), BRI endpoint (BRI-SET), or
ASAI adjunct (ASAI-ADJ/LGATE-AJ/LGATE-AJ) or Avaya adjunct
(ATT-ADJ/ATTE-AJ). These interactions should be kept in mind when
investigating the cause of ISDN-BRI port problems. For more information about
the circuit pack, see:
''BRI-BD/LGATE-BD (ISDN-BRI Line Circuit Pack)'' on page 8-321
''BRI-SET, ASAI-ADJ, BRI-DAT'' on page 8-354
and its endpoints, see:
ASAI-ADJ (Adjunct-Switch Application Interface)
ATT-ADJ (Avaya Adjunct) Maintenance documentation
''LGATE-AJ'' on page 8-1013
ATTE-AJ (Ethernet Avaya Adjunct) Maintenance documentation
Switch
circuit pack
Figure 8-11. ISDN-BRI Port Interactions
8-332
Issue 1 May 2002
BRI line
D-channel
B-channel
Port
B-channel
Logical connection
Physical connection
Voice or
data terminal
Voice or
data terminal
bripor1 LJK 072501