Maintenance-Object Repair Procedures
Table 8-85. Expansion Interface 2-Way Transmission Test (#241)
Error
Test
Code
Result
Description / Recommendation
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1002
ABORT
The system could not allocate time slots for the test. The system could be
under heavy traffic conditions or it can have time slots out of service due to
TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
1003
ABORT
The system could not allocate a tone receiver for the test. The system may be
oversized for the number of Tone Detectors present, or some Tone Detectors
may be out of service.
1. Resolve any TTR-LEV errors.
2. Verify that at least one Tone Detector resides in this EPN. (Even without a
3. Resolve any TONE-PT errors.
4. If neither condition exists, retry the command at 1-minute intervals up to 3
8-206
Issue 1 May 2002
retry the command at 1-minute intervals up to 3 times.
TTR-LEV error, the tested circuit pack's EPN could be missing a Tone
Detector.)
If missing, the test always aborts for this circuit pack, without harming the
system.
NOTE:
A TN2182 Tone-Clock circuit pack in an EPN must be of vintage B or
newer. If an earlier vintage resides in an EPN, this test always aborts
with this abort code.
times.
Continued on next page