ATM-TRK (Circuit Emulation Service Circuit Pack)
Control Channel Loop Test (#52)
The nondestructive Control Channel Loop test is part of the maintenance
subsystem's Common Port Board Testing feature. The Common Port Board test
sends board vintage queries to a port circuit pack and checks the responses.
CCMS downlink notifications tell the circuit pack which TDM Bus (A or B) carries
the control channel and which carries the touch tones.
The test passes if the port circuit pack responds. The test aborts if the circuit pack
does not respond. The test fails otherwise.
Table 8-123.
Control Channel Test #52
Error
Test
Code
Result
Description / Recommendation
2000
ABORT
Test request timed out.
2100
ABORT
Could not allocate needed system resources.
2500
ABORT
Internal system error
1. Retry the command up to 3 times at 1-minute intervals.
FAIL
The ATM circuit pack responded incorrectly.
1. Retry the command up to 3 times at 1-minute intervals.
2. If the test continues to fail, reset the ATM-TRK circuit pack (reset board
3. If test continues to fail, replace the circuit pack or transceiver.
PASS
The ATM-TRK circuit pack is communicating correctly with the software.
0
NO
Circuit pack not detected.
BOARD
1. Check the error log for Error 125 (wrong board) or Error 131 (no board),
2. Make sure that the ATM-TRK circuit pack is properly translated and
3. Check for Error 1538 (hyperactivity). If hyperactive, run reset board
4. Run the test again. If it fails, replace the ATM-TRK circuit pack, and retest.
555-233-143
UUCSS).
and correct any errors found.
inserted.
UUCSS.
Continued on next page
Issue 1 May 2002
8-287