ANN-PT (Announcement Port)
Table 8-53. Test #205 CAMA (Channel Administration Memory Array)
Test — Continued
Error
Test
Code
Result
Description / Recommendation
FAIL
Test failed. Announcements played back on this port may sound corrupted.
1. Reset the circuit pack using the reset board UUCSS command and then
2. If there are recurring alarms on this port caused by this test failing, replace
!
PASS
This test verifies that the Angel processor can properly set up this port for
playbacks. User-reported troubles on this circuit pack should be investigated
using other port and circuit pack tests. (Refer to
Port)''
555-233-143
run this test again. If the test continues to fail, replace the circuit pack.
the circuit pack even if step 1 works.
CAUTION:
Replacing the circuit pack causes a loss of integrated announcements.
Refer to
''Essential Service Information'' on page 8-120
MO.
for a description of the circuit pack tests.)
of the AN-LN-PT
''AN-LN-PT (Analog Line
Continued on next page