Maintenance-Object Repair Procedures
ADX16D-B (16-Port AUDIX Circuit
Pack)
MO's Name (in
Alarm Log)
ADX16D-B
ADX16D-B
1.
UU is the universal cabinet number (1–64 for ATM PNC, 1–44 for CSS PNC). C is the carrier
designation (A, B, C, D, or E). SS is the number of the slot where the circuit pack resides (01–21).
The ADX16D-BD MO represents a TN566/TN2169 EMBEDDED AUDIX circuit
pack combination operating in 16-port mode digital (DP). For circuit-pack-level
problems, see
maintenance is covered by ADX16D-PT.
EMBEDDED AUDIX consists of two circuit packs that occupy 5 slots on a port
carrier. The tests described in this manual apply only to switch-side maintenance
that tests a circuit pack's components related to the TDM-bus interface. The
AUDIX system has an extensive maintenance strategy of its own that is described
in EMBEDDED AUDIX System Maintenance, 585-300-110.
8-24
Issue 1 May 2002
Alarm
Level
Initial Command to Run
MINOR
test board UUCSS sh
WARNING
test board UUCSS sh
''XXX-BD (Common Port Circuit Pack)'' on page
1
Full Name of MO
AUDIX circuit pack
AUDIX circuit pack
8-1872. Port-level
555-233-143