EXP-PN (Expansion Port Network)
Table 8-313. Test #955 PN Cold Restart
Error
Test
Code
Result
Description / Recommendation
1386
ABORT
The system link to this PN is unavailable and cannot be used. This reset
cannot be executed without the link being operational.
1. Refer to SYS-LINK and resolve the link problem.
2100
ABORT
Could not allocate the necessary system resources to execute this reset.
2000
ABORT
Response to a request made in the internal portion of this reset procedure was
not received within the allowable time period.
2500
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
FAIL
Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
PASS
The PN Cold Restart procedure completed successfully.