Maintenance-Object Repair Procedures
NPE Crosstalk Test (#6)
This test verifies that the port's NPE channel talks on the selected time slot and
never crosses over to time slots reserved for other connections. If the NPE is not
working correctly, 1-way and noisy connections may be observed. This test is
usually part of the long test sequence and executes in about 20 to 30 seconds.
Table 8-40. Test #6 NPE Crosstalk Test
Error
Test
Code
Result
Description / Recommendation
ABORT
Necessary system resources could not be allocated to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
1000
ABORT
System resources are unavailable. The port may be busy with a valid call.
This result is also reported for the system's Music-On-Hold port when it is
off-hook, which it usually is.
1. Enter display port UUCSSpp to determine the station's extension.
2. Enter status station extension to determine the service state of the port.
3. If the port is active, wait until it is idle. Retry the command at 1-minute
4. If the test continues to abort, escalate the problem.
1001
ABORT
System resources required to run test are not available. This could be due to a
failure to seize the port.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
1002
ABORT
The system could not allocate time slots for the test. The system may be under
heavy traffic conditions or have time slots out-of-service due to TDM-BUS
errors.
1. Refer to "TDM-BUS" to diagnose any active TDM-BUS errors.
2. If the system has no TDM-BUS errors and is not handling heavy traffic,
3. If the test continues to abort, escalate the problem.
1003
ABORT
The system could not allocate a tone receiver for the test. The system may be
oversized for the number of Tone Detectors present or some Tone Detectors
may be out-of-service.
1. Resolve any TTR-LEV errors in the Error Log.
2. Resolve any TONE-PT errors in the Error Log.
3. If neither condition exists, retry the command at 1-minute intervals up to 5
4. If the test continues to abort, escalate the problem.
8-104
Issue 1 May 2002
intervals up to 5 times.
retry the command at 1-minute intervals up to 5 times.
times.