Avaya S8700 Maintenance Manual page 1136

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
e. Error Type 513: Circuit pack detected and reported hardware failure.
1. Reset the circuit pack (reset board UUCSS).
Aux Data:
4352
4353
4355
4356
4357
f. Error Type 769: Logic error. By itself this error may be ignored, but it may
result in other error types being reported.
g. Error Type 1293-1295: Critical hardware or firmware error.
If the switch detects:
1 error,
3 errors in 15 minutes,
Error Type descriptions are as follows:
1293
1294
1295
1. Attempt to clear the alarm (reset board UUCSS).
2. If alarm persists, replace circuit pack.
h. Error Type 1537: Switch removed hyperactive circuit pack that reported
threshold number of errors.
1. Attempt to clear the alarm (reset board UUCSS).
2. If the error recurs within 15 minutes, replace the circuit pack.
i. Error Type 1794: Packet-bus transmit buffers have overflowed.
1. Attempt to clear the alarm (reset board UUCSS).
2. If the error recurs within 15 minutes, replace the circuit pack.
j. Error Type 1798: Unable to write translation RAM.
1. Attempt to clear alarm (reset board UUCSS).
2. If alarm recurs within 15 minutes, replace the circuit pack.
8-414
Issue 1 May 2002
External RAM error
Internal RAM error
ROM Checksum error
Angel Message Corruption error
Instruction set error
Then the switch:
Resets circuit pack.
Raises MINOR alarm.
Insane onboard processor
Onboard translation RAM error
(Aux 3) RSCL link down
(Aux 0) RSCL keep alive failure
555-233-143