Maintenance-Object Repair Procedures
Table 8-201. Test #171 Digital Loop-Around Test — Continued
Error
Test
Code
Result
Description / Recommendation
1392
ABORT
This port is currently a TTI port and the test will not execute on it.
1. Verify that the port is a TTI port using either the display port command
2. If either list config or display port indicates that the port is not a TTI port,
2000
ABORT
Response to the test request was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2. Escalate the problem if the test continues to abort.
2004
ABORT
Off hook was not received from the data line device.
1. Busyout the digital port being tested on the data line circuit pack. Retry the
2. If the test still aborts, replace the circuit pack.
2005
ABORT
The handshake between the Maintenance/Test circuit pack digital port and the
data line port failed.
1. Resolve any M/T-DIG errors.
2. Retry the command at 1-minute intervals up to 5 times.
3. If the test still aborts, replace the data line circuit pack.
2312
ABORT
Test did not finish, did not receive loop back data.
1. Resolve any M/T-DIG errors.
2. Retry the test, if still aborts, replace the Data Line circuit pack.
2313
ABORT
Failed to receive a response from the Maintenance/Test digital port.
1. Resolve any M/T-DIG errors.
2. Retry the command at 1-minute intervals up to 5 times.
3. If the test continues to abort, replace the Maintenance/Test circuit pack.
2314
ABORT
Data line port did not respond to downlinked message.
1. Busyout the digital port being tested on the data line circuit pack. Retry the
2. If the test still aborts, replace the circuit pack.
8-496
Issue 1 May 2002
(the display shows that the port is a TTI port) or the list config command
(the display shows a "t" for the port).
escalate the problem. If both commands indicate that the port is a TTI port,
the abort is correct for the test, and no action is necessary.
command at 1-minute intervals up to 5 times.
command at 1-minute intervals up to 5 times.