Avaya S8700 Maintenance Manual page 824

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
Error log entries and test to clear values
Table 8-39. Analog line error log entries
Error
Aux
Type
Data
Associated Test
1
0
0
Any
1(a)
40960
none
40975
40977
15(b)
Any
Audits and Updates test
(#36)
18
0
busy station extension
130(c)
None
257(d)
40973
none
513(e)
Station Present test (#48)
769
Battery Feed test (#35)
1025
Looparound test (#161)
1281
Conference test (#7)
1537
NPE Crosstalk test (#6)
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test's description, and follow its recommended procedures.
2.
Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the set options
command.
Notes:
a. Error Type 1: these are in-line errors and can only be resolved over time.
8-102
Issue 1 May 2002
Alarm
Level
Any
WARNING
WARNING
WARNING
MINOR
WARNING
MINOR
WARNING
MINOR
WARNING
MINOR
WARNING
Aux Data 40960 indicates that too many simultaneous incoming
ringing attempts were made on this board. Only 4 ports on a board
may ring simultaneously. A 5
error from the board.
Aux Data 40975 indicates that the terminal equipment was on-hook
when ring-tip was detected during ringing. This usually indicates a
failure in the terminal equipment or the type of terminal has a low
ringer impedance.
1. Call the terminal equipment and verify that the terminal rings.
2. If the terminal does not ring, then replace it.
3. Otherwise, issue the test port UUCSSpp command, and
follow the procedure for Test #48.
On/Off
Board
Test to Clear Value
Any
test port UUCSSpp sh r 1
ON
release station extension
ON
test port UUCSSpp sh
OFF
test port UUCSSpp sh r 2
ON
test port UUCSSpp sh r 2
2
ON
test port UUCSSpp l r 2
2
ON
test port UUCSSpp l r 2
2
ON
test port UUCSSpp l r 2
2
th