Avaya S8700 Maintenance Manual page 1680

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
See
Table 8-377
ipserver-interface command:
Table 8-377. Error codes for set ipserver-interface
Error
Command
Code
Result
Description
PASS
The interchange was successful, or the set to IPSI was already active. If set
to a B-side IPSI, it will be marked as "craft set" and will not preference switch
back to the A-side by software.
2338
FAIL
The SOH of the set-to IPSI is bad. Use list ipserver-interface to display the
current IPSI's SOH.
2340
The archangel function is not on an IPSI.
2341
An error occurred during the interchange.
2342
The set-to IPSI has been busied out.
Run release ipserver-interface Uc first.
2343
ABORT
Interchange not permitted. The anti-thrashing timer has not yet expired.
Retry command in 30 seconds.
8-958
Issue 1 May 2002
for ABORT/FAIL codes associated with the set
555-233-143