Maintenance-Object Repair Procedures
Table 8-310. Test #589 Expansion Interface Packet Interface Test — Continued
Error
Test
Code
Result
Description / Recommendation
1033
ABORT
3. If Test #237 passes, reseat the EI circuit pack. This will not be destructive
(cont'd.)
(cont'd.)
4. Repeat Test #237.
CENTER STAGE
If the EI circuit pack under test resides in the PN:
None of the EI circuit packs located in the PNs (on the same PNC side) are in
service (for PN EIs see the next case).
1. Issue the list fiber-link command to determine whether any of the PN's EI
2. Issue the list conf command for the cabinets and carriers where the EI
3. Issue the display errors command, and resolve any EXP-PN errors.
4. If the test continues to abort with this error code, reseat the EI circuit packs
5. Run Test #237 on each of the PN EI circuit packs, and check for EXP-INTF
6. Repeat this test.
1033
ABORT
If the EI circuit pack under test resides in the PN:
(cont'd.)
(cont'd.)
The EI circuit located in the PN is out of service.
1. Run Test #237 on each of the PN EI circuit packs and check for EXP-INTF
2. Repeat this test.
1139
ABORT
The packet bus in the PN where this EI circuit pack resides has a major alarm
against it. This test needs to use the alarmed port network's packet bus.
1. Enter display alarms and resolve any PKT-BUS alarms.
2. Retry the command.
8-812
Issue 1 May 2002
since the circuit pack cannot be serving as the Expansion Archangel if it is
not in service.
circuit packs are administered as endpoints of a fiber link. If not, then ignore
the results of this test.
circuit packs reside in every other PN. If the results returned indicated that
the circuit packs are not recognized by software, they are out of service for
this reason.
Re-execute this test.
(or DS1 CONV circuit pack if so equipped) on the PNs. This will not be
destructive since the circuit pack cannot be serving as the Expansion
Archangel if it is not in service.
circuit pack Error Type 1281 in the error log. If Error Type is present and/or
Test #237 does not pass, see repair procedures for Test #237, in
8-303 on page
8-787.
circuit pack Error Type 1281 in the error log. If Error Type is present and/or
Test #237 does not pass, see repair procedures for Test #237, on page
8-787.
Table
Continued on next page
555-233-143