Maintenance-Object Repair Procedures
Table 8-246. Test #139 Blue Alarm Inquiry Test — Continued
Error
Test
Code
Result
Description / Recommendation
1794
FAIL
The DS1 Interface circuit pack detects a Line Loopback Alarm (LLB).
1. If the DS1 interface circuit pack connects to a T1 facility, call the vendor of
2. If the DS1 interface circuit pack connects directly to a switch, call the
3. If the DS1 interface circuit pack connects directly to a line-side terminating
1795
FAIL
The DS1 Interface circuit pack detects a Payload Loopback Alarm (PLB). If the
DS1 Interface circuit pack connects to a leased T1 facility, call the vendor of the
T1 carrier to diagnose the remote DS1 endpoint. If the DS1 Interface circuit
pack connects directly to another DS1 board, call the system technician of the
remote switch to diagnose the DS1 endpoint.
PASS
Remote DS1 endpoint is in-service. Neither a Blue alarm nor a Line Loopback
alarm nor a Payload Loopback alarm is detected in the DS1 Interface circuit
pack.
0
NO
The test could not relate the internal ID to the port (no board).
BOARD
This could be due to incorrect translations, no board is inserted, an incorrect
board is inserted, or an insane board is inserted.
1. Verify that the board's translations are correct. Use the add ds1 UUCSS
2. If board was already administered correctly, check the error log to
3. If the board was found to be correctly inserted in step 1, issue the busyout
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
8-612
Issue 1 May 2002
the T1 carrier to diagnose the remote DS1 endpoint.
system technician of the remote switch to diagnose the DS1 endpoint.
device (for example, a PRI terminal adapter), call the vendor of the
terminating device to diagnose the equipment.
command to administer the DS1 interface if it is not already administered.
determine whether the board is hyperactive. If so, the board was shut
down. Reseating the board will re-initialize it.
board command.
This should re-establish the link between the internal ID and the port.
Continued on next page
555-233-143