Maintenance-Object Repair Procedures
Table 8-262. Test #1227 ICSU Status LEDs Test
Error
Test
Code
Result
Description / Recommendation
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
1005
ABORT
The ICSU Status LEDs test cannot be executed for the current configuration.
The test applies only to TN767E or later DS1 circuit packs administered for
24-channel (1.544-Mbps) operation.
1. If the circuit pack is a TN767E (or higher-suffixed) DS1 circuit pack, then
1951
ABORT
The ICSU Status LEDs test cannot be executed because a 120A1 (or
higher-suffixed) CSU module or a 401A (or higher-suffixed) T1 sync splitter is
not physically installed. If using a 120A1 CSU module
physically connect it to the TN767E board behind the port carrier. Otherwise,
ignore this abort.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2500
ABORT
Internal system error.
1. Retry the command.
PASS
The ICSU Status LEDs test executed successfully. A PASS result, however,
does not necessarily mean that the status LEDs behaved properly. It only
means that the software successfully attempted to light the status LEDs. This
is a visual test. The service technician must visually exam the behavior of the
LEDs while the test is running. The LEDs are functioning properly if the four
status LEDs are lit red for 5 seconds, then lit green for 5 seconds, then lit
yellow for 5 seconds. If the LEDs behave differently, escalate this problem.
0
NO
The test could not relate the internal ID to the port (no board).
BOARD
This could be due to incorrect translations, no board is inserted, an incorrect
board is inserted, or an insane board is inserted.
1. Verify that the board's translations are correct. Use the add ds1 UUCSS
2. If board was already administered correctly, check the error log to
3. If the board was found to be correctly inserted in step 1, issue the busyout
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
8-658
Issue 1 May 2002
retry the command.
command to administer the DS1 interface if it is not already administered.
determine whether the board is hyperactive. If so, the board was shut
down. Reseating the board will re-initialize it.
board command.
This should re-establish the linkage between the internal ID and the port.
/T1 sync splitter
,
Continued on next page