Avaya S8700 Maintenance Manual page 1577

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

FIBER-LK (Fiber Link)
Table 8-328. Test #759 Configuration Audit — Continued
Error
Test
Code
Result
Description / Recommendation
212
FAIL
The SNI circuit pack (Endpoint 2) cannot communicate with the active SNC.
(The list fiber-link command displays a fiber link's endpoints.)
1. Check the error log for other SNI circuit packs in the same carrier with a
2. Replace this SNI.
3. Replace the active SNC in the same switch node carrier.
213
FAIL
The SNI circuit pack (Endpoint 2) cannot communicate with the equipped SNI
in slot 13. (The list fiber-link command displays a fiber link's endpoints.)
1. Perform the
2. If the SNI being tested has SNI-PEER Error Type 2049, replace the SNI
3. If the SNI being tested still has SNI-PEER Error Type 2049, replace the
214
FAIL
The SNI circuit pack (Endpoint 2) cannot communicate with the equipped SNI
in slot 14. (The list fiber-link command displays a fiber link's endpoints.)
1. Perform the
2. If the SNI being tested has SNI-PEER Error Type 2305, replace the SNI
3. If the SNI being tested still has SNI-PEER Error Type 2305, replace the
555-233-143
257 SNI-BD error. Use display errors with category PNC to view SNI-BD
errors. If other SNI circuit packs in the same switch node carrier have error
257, then replace the active SNC in this switch node carrier. Replacing an
SNC may be service interrupting. Refer to the SNC-BD section for the
procedure for replacing an SNC.
''Fault Isolation for Fiber Links'' on page
resolve multiple SNI-PEER errors.
being tested. (Replacing an SNI may be service interrupting. Refer to the
SNI-BD section for the procedure to replace an SNI.) To view SNI-PEER
errors, use the display errors command with category PNC-PEER. Retry
the command.
SNI in slot 13.
''Fault Isolation for Fiber Links'' on page
resolve multiple SNI-PEER errors.
being tested. (Replacing an SNI may be service interrupting. Refer to the
SNI-BD section for the procedure to replace an SNI.) To view SNI-PEER
errors, use the display errors command with category PNC-PEER. Retry
the command.
SNI in slot 14.
4-19. This should
4-19. This should
Continued on next page
Issue 1 May 2002
8-855