Avaya S8700 Maintenance Manual page 1723

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

ISDN-TRK (DS1 ISDN Trunk)
Audit and Update Test (#36)
This test sends port level translation data from switch processor to the DS1
interface circuit pack to assure that the trunk's translation is correct. The port
audit operation verifies the consistency of the current state of trunk kept in the
DS1 interface circuit pack and in the switch software.
Table 8-396. Test #36 Audit and Update Test
Error
Test
Code
Result
Description / Recommendation
1018
ABORT
Maintenance is disabled on this trunk.
1. Enable maintenance by entering ''y'' in the ''Maintenance Tests?'' field on
ABORT
Internal system error
2000
ABORT
Response to the test request was not received within the allowable time period.
2100
ABORT
Could not allocate the necessary system resources to run this test.
FAIL
Test failed due to internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
PASS
Trunk translation has been updated successfully. The current trunk states kept
in the DS1 interface circuit pack and switch software are consistent.
555-233-143
page 2 of the change trunk-group form.
Continued on next page
Issue 1 May 2002
8-1001

Advertisement

Table of Contents
loading

Table of Contents