ASAI-PT
Figure 8-2. BRI Port Local LAN Loop-Around Path
Table 8-61. Test #618 BRI Port Local LAN Looparound
Error
Test
Code
Result
Description / Recommendation
1015
ABORT
The port is not in the out-of-service state.
1. Display the Port Status form using the status bri-port UUCSSpp
2. Use the extension shown on this form in the status station command to
3. If the port is active, wait until it is idle, and use the busyout port UUCSSpp
!
1139
ABORT
The EPN's packet bus is out-of-service.
1. Follow the repair procedures for the packet bus.
2. After completing step 1, execute the test port long UUCSSpp command
555-233-143
. .
.
.
.
.
.
.
.
.
.
.
.
.
. .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. . . .
.
BRI LINE
CIRCUIT
PACK
command to determine which stations or adjuncts are on this port.
determine whether the station or adjunct is active.
command to place it in the out-of-service state and repeat this test.
WARNING:
Since the "busyout" command is destructive, using this command prior to
the port being idle causes every transaction associated with the ASAI on
the port to be torn down. Note that 3
adjunct remain connected even though the port is taken out-of-service.
and review the results of the BRI Port Local LAN Looparound test to verify
the repair.
PACKET
INTERFACE
.
.
.
.
.
.
.
.
.
.
.
.
. .
.
.
.
.
.
.
.
.
.
.
.
. .
rd
-party calls established by an ASAI
Continued on next page