Maintenance-Object Repair Procedures
Table 8-395. Test #7 Conference Circuit Test
Error
Test
Code
Result
Description / Recommendation
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABORT
System resources required to run this test are not available. The port may be
in use on a valid call. Use status station or status trunk commands to
determine when the port is available for testing.
1004
ABORT
The port has been seized by a user for a valid call. Use status station or status
trunk to determine when the port is available for testing.
1. Retry the command at 1-minute intervals up to 5 times.
1018
ABORT
Maintenance is disabled on this trunk.
1. Enable maintenance by entering ''y'' in the ''Maintenance Tests?'' field on
1020
ABORT
The test did not run due to an already existing error on the specific port or a
more general circuit pack error.
1. Examine Error Log for existing errors against this port or the circuit pack
2000
ABORT
Response to the test request was not received within the allowable time period.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
Any
FAIL
The NPE of the tested port did not conference the tones correctly. This will
cause noisy and unreliable connections.
1. Replace the circuit pack.
PASS
The port can correctly conference multiple connections. User-reported troubles
on this port should be investigated using other port tests and examining station,
trunk, or external wiring.
8-1000
Issue 1 May 2002