Maintenance-Object Repair Procedures

E-DIG-STA (Emulated Digital Line)

MO's Name (in
Alarm Log)
E-DIG-STA
E-DIG-STA
1.
Where UU is the universal cabinet number (1–64 for ATM PNC, 1–44 for CSS PNC); C is the
carrier designation (A, B, C, D, or E); SS is the address of the slot in the carrier where the circuit
pack resides (1 – 21); and pp is the 2-digit port number (01, 02, 03, ...).
There are 4 tests in the Emulated Digital Line station maintenance test sequence
and only one test path in the test sequence. Once the test sequence begins,
every test in the test sequence is executed.
E-DIG-ST maintenance monitors and tests ports on the TN800 MAPD circuit pack
and the hardware connected to those ports for lines administered as a digital
station. These include stations with an emulated digital voice terminal and
stations with an emulated digital voice terminal and a linked data module.
Stand-alone data modules and data adaptors in stand-alone mode are not
supported by the TN800 circuit pack. Circuit pack maintenance is covered by
E-DIG-BD.
8-726
Issue 1 May 2002
Initial SAT Command to
1
(a) (b)
Alarm Level
Run
MINOR
test port UUCSSpp l
WARNING
test port UUCSSpp sh
Full Name of MO
Emulated Digital St.
Emulated Digital St.