Advertisement

Maintenance-Object Repair Procedures
c. Rotary dial too early — This condition occurs when the CO starts dialing
too soon after seizure on an immediate-start trunk.
1. Verify trunk administered wink/immediate-start parameter.
2. Refer problem to CO.
d. Rotary dial pulse during wink — This condition occurs when the CO sends
rotary dial digits too soon after seizure on a wink-start trunk.
1. Verify trunk administered wink/immediate-start parameter.
2. Refer problem to CO.
e. This is a software audit error that does not indicate any hardware
malfunction. Run short test sequence, and investigate associated errors (if
any).
f. This error type indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
g. Rotary dial pulse on-hook longer than 105 msec — Break between rotary
pulses is too long.
1. Test trunk by performing an incoming test call.
2. Refer problem to CO.
h. Rotary dial rate below 8 pulses/sec — More than 135 msec between two
successive breaks.
1. Verify trunk administered interdigit-timing parameters.
2. Refer problem to CO.
i. Rotary dial rate above 12 pulses/sec — Less than 75 msec between two
successive breaks.
1. Verify trunk administered interdigit-timing parameters.
2. Refer problem to CO.
j. Digit detection — CO is starting new rotary dial digit within 150 msec of
previous digit.
1. Verify trunk administered interdigit timing parameters.
2. Refer problem to CO.
8-518
Issue 1 May 2002
555-233-143