Avaya S8700 Maintenance Manual page 1732

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
Table 8-400. Test #258 ISDN Test Call — Continued
Error
Test
Code
Result
Description / Recommendation
2038,
ABORT
A problem occurred while trying to read the test data.
2039
1. Wait 1 minute and then try again. If the test aborts again in the same
2040
ABORT
Internal system error. Follow recommendations for ABORT code 2012.
2041
ABORT
The call has timed out, perhaps because of a lack of system resources. Follow
recommendations for ABORT code 2035.
2066
ABORT
Could not establish test call.
1. Retry the command at 1-minute intervals up to 5 times.
2067
ABORT
The call has timed out, perhaps because of a lack of system resources. Follow
recommendations for ABORT code 2035.
2074
ABORT
Bit and Block Error query failed.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, there may be a serious internal problem with
2075
ABORT
Internal system error. Follow recommendations for ABORT code 2012.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2104
ABORT
Call dropped or could not be originated.
1. Make sure service is provisioned by the network.
2. Check the administration of the far-end test line extension on the trunk
3. Check the administration of the Testcall BCC (Bearer Capability Class) on
4. Check the reason for termination with status isdn-testcall.
5. For further instructions see
6. Try the test again.
2201,
ABORT
Internal system error. Follow recommendations for ABORT code 2012.
2202,
2203,
2204,
2205
2206
ABORT
Could not allocate the necessary system resources to run this test. Follow
recommendations for ABORT code 2100.
2208
ABORT
Internal system error. Follow recommendations for ABORT code 2012.
8-1010
Issue 1 May 2002
manner, there is a serious internal problem.
M/T-DIG (Maintenance/Test Digital Port). If this is the case,
(Maintenance/Test Digital
group administration form.
the trunk group administration form.
Port)''.
''Troubleshooting ISDN-PRI Test
Continued on next page
see''M/T-DIG
Calls''.
555-233-143

Advertisement

Table of Contents
loading

Table of Contents