Avaya S8700 Maintenance Manual page 1228

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
Maintenance does not start any testing or generate any alarms in response
to these errors.
b. Error Type 15—This is a software audit error that does not indicate any
hardware malfunction. Run short test sequence, and investigate errors (if
any).
c. Error Type 18—The trunk has been taken out of service by a demand
busyout. No calls can be made on this trunk.
d. Error Type 130—This error type indicates that the circuit pack has been
removed or has been insane for more than 11 minutes. To clear the error,
reinsert or replace the circuit pack.
e. Error Type 257—DS1 Interface circuit pack detects a hardware error on
the DS1 DID trunk. The Aux Data field indicate the source of the error:
57474
57473
f. Error Type 513—DS1 Interface circuit pack detects a hardware error on
the DS1 DID trunk. Aux Data 57392 indicates no external release on PBX
disconnect.
g. Error Type 769—DS1 Interface circuit pack detects a hardware error on
the DS1 DID trunk. Aux Data 57393 indicates belated external release on
PBX disconnect.
h. Error Type 1793—DS1 Interface circuit pack is out-of-service. Look for
DS1-BD/UDS1-BD errors in Hardware Error Log. Refer to the appropriate
"DS1-BD/UDS1-BD" information for details.
i. Error Type 2305—This error indicates that a signaling change was
detected by the PBX trunk circuit pack which is inconsistent with the
present state of the trunk.
j. Error Type 3840—Port Audit and Update test (#36) failed due to an
internal system error. Enter status trunk command to verify the status of
the trunk. If the trunk is out-of-service, then enter the release trunk
command to put it back to in-service. Retry the test command.
8-506
Issue 1 May 2002
Rotary dial rate above 12 pulses per second
Rotary dial rate below 8 pulses per second
555-233-143