Table 8-398. Test #256 Service State Audit Test — Continued
Error
Test
Code
Result
Description / Recommendation
1114
ABORT
The signaling link is in a transitional state.
1. Retry the command at 1-minute intervals up to 5 times.
1116
ABORT
The trunk is not in the out-of-service/far-end state that is required to run this
test on systems using a country protocol other than 1.
1117
ABORT
A service state audit message is outstanding.
1. Wait 2 minutes and then try again.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1113
FAIL
The signaling link has failed; the system cannot send any messages on behalf
of this trunk.
1. Consult procedures for ISDN-SGR (ISDN-PRI Signaling Group) and
FAIL
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
PASS
Wait 4 minutes and then check the Error Log for any new errors of type 3073. If
there are none, then both sides of the ISDN connection agree on the service
state; the negotiation succeeded. If there is a new 3073 error, then the
negotiation failed (the far-end switch twice failed to respond within 2 minutes).
The switch will automatically retry every 15 minutes. If the trunk was initially in
service, it is now placed in the maintenance/far-end state. Incoming calls will
be accepted, but no outgoing calls can be originated. If an incoming call is
presented, another Service State Audit will be immediately performed in an
attempt to put the DS1 ISDN Trunk in the proper state.
8-1004
Issue 1 May 2002
ISDN-LNK (ISDN Signaling Link Port).