Maintenance-Object Repair Procedures
ATM Cross Talk Test (#1298)
This nondestructive ATM Cross Talk test makes sure that TDM time slots are
correctly allocated to connections. It is useful for diagnosing one-way or noisy
connections. The test fails if the TDM programmable logic and/or the interface to
the DSP is not operating properly. The test can take more than 10 minutes.
Figure 8-7 on page 8-225
for "PNC mode."
Table 8-132.
ATM Crosstalk Test (#1298)
Error
Test
Code
Result
Description / Recommendation
ABORT
Could not allocate required system resources.
1. Retry the command up to 5 times at 1-minute intervals.
1002
ABORT
Could not allocate time slots. Traffic could be heavy or time slots could be
out-of-service.
1. Identify and correct TDM-bus errors (if any) using the procedures in the
2. Repeat the test up to 5 times at 1-minute intervals.
1003
ABORT
Could not allocate a tone receiver. Too few Tone Detectors installed or Tone
Detectors out-of-service.
1. Identify and correct any TTR-LEV (TTR Level) errors listed in the Error
2. Resolve any TONE-PT (Tone Generator) errors listed in the Error Log.
3. Retry the test up to 5 times at 1-minute intervals a maximum.
2000
ABORT
Test timed out.
2100
ABORT
Could not allocate required system resources
1. Retry the command 5 times at 1-minute intervals.
1962
ABORT
Every TALKER DSP is busy.
2302
ABORT
Inconsistent uplink message from the ATM-TRK circuit pack.
1. Retry the command up to 3 times at 1-minute intervals.
2752
ABORT
The circuit pack in this location is not a TN2305A/2306A.
8-300
Issue 1 May 2002
shows a diagram of this test, substituting "CES mode"