Table 8-306. Test #241 Expansion Interface 2-Way Transmission Test
Error
Test
Code
Result
Description / Recommendation
1002
ABORT
The system could not allocate time slots for the test. The system may be under
heavy traffic conditions or it may have time slots out of service due to
TDM-BUS errors. Enter display errors and follow associated repair
procedures for TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
1003
ABORT
The system could not allocate a tone receiver for the test. The system may be
oversized for the number of tone detectors present or some tone detectors may
be out of service.
1. Enter display errors and follow associated repair procedures for TTR-LEV
2. Enter display errors and follow associated repair procedures for
3. If neither condition exists, retry the command at 1-minute intervals up to 3
8-794
Issue 1 May 2002
retry the command at 1-minute intervals up to 3 times.
errors in the error log. Even if there are not TTR-LEV errors, there may not
be a tone detector available on the network that contains the circuit pack
being tested. Verify that there is at least one tone detector on this network.
If not, this test will always abort for this EI circuit pack. This will not harm
the system in any way.
NOTE:
S8700 Multi-Connect systems require that Tone Detector circuit packs
(TN768) must be of vintage "B" or newer. If older Tone Detector circuit
packs are installed in the system, this test will always abort with this
code.
TONE-PT errors.