Avaya S8700 Maintenance Manual page 821

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

ANL-LINE, ANL-NE-L (8-Port Analog Line)
Table 8-38. Test #48 Station Present Test — Continued
Error
Test
Code
Result
Description / Recommendation
1005
ABORT
The test was aborted due to a configuration problem. This code occurs under
either of the following conditions:
1. This test may not be applicable, or it may be disruptive to terminal
2. The circuit pack is one of the following:
1008
ABORT
Could not allocate a ringing circuit for one of the following reasons: (1) every
ringing circuit is active, or (2) the ringing generator is defective, or (3) it is
incorrectly wired.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, look for RING-GEN errors in the Error Log. If
1018
ABORT
The test was disabled via administration. The default for the
thus, you may want to determine why this field has been set to "n" on this
station (this may be due to the ringing application Test #48, which can be
customer or terminal disturbing).
1. To enable the test for a particular station, enter change station extension
2000
ABORT
Response to the test request was not received within the allowable time period.
2100
ABORT
System resources required to run this test are not available. Either a system
allocation to get information about the port or to put the port into a service state
failed or the attempt to put the port in connection with a tone source failed (this
could be a Tone-Clock problem). The Tone-Clock and Tone Detectors could
be having a communication problem. (For example, the companding modes
could be out of synchronization.)
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
555-233-143
equipment other than a voice terminal (for example, the modem pool
member or music on hold).
— TN742 vintages 13, 14, and 15
— TN769 vintages 3, 4, and 5
an ABORT 1008 occurs for Test #48 on other circuit packs as well, then the
ringing generator may be defective or incorrectly wired. If it does not occur
on other ports, then that circuit pack is currently using all four ringing
phases.
and set the
field to y.
Test?
field is y;
Test?
Continued on next page
Issue 1 May 2002
8-99