Avaya S8700 Maintenance Manual page 1462

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
Table 8-288. Test #124 Emergency Transfer Query Test
Error
Test
Code
Result
Description / Recommendation
1000
ABORT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2000
ABORT
Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to ABORT with Error Code 2000, check for system
3. If the test continues to ABORT with a 2000 Error Code, resolve every or
2029,
ABORT
Internal system error
2319,
1. Retry the command at 1-minute intervals up to 5 times.
2320,
2500
17,
FAIL
Emergency Transfer is manually turned OFF (Emergency Transfer switch off).
18,
1. Place the switch in the AUTO position.
20,
33,
65,
289
34,
FAIL
Emergency Transfer is manually turned ON (Emergency Transfer switch on).
290
1. Place the switch in the AUTO position.
PASS
System software has control of Emergency Transfer within this cabinet. If
Emergency Transfer is currently invoked (the emergency transfer LED is on),
the cause could be a major alarm.
1. The following list shows the error types that can cause Emergency
2. If none of the previous errors appear in the log, then check the Emergency
3. On an EPN, if Emergency Transfer is invoked while call processing is
8-740
Issue 1 May 2002
powering problems with the PN's A carrier. Resolve every AC-POWER
and CARR-POW alarm in a multicarrier cabinet system or DC-POWER
alarm in a single-carrier cabinet system. Then, repeat the test.
MAINT (Maintenance circuit pack) error in an PN. Then, repeat the test.
Transfer. If any of these errors appear in the log, then see
(Tone-Clock
Circuit)'', and resolve these error types first:
Error Type 3585 Aux Data 121
Error Type 2305, Aux Data 40800
Transfer hardware.
permitted, verify that the current limiter card (982LS) is in the correct slot
on the backplane. If the current limiter card is not in the correct slot, move
it to the correct location, and rerun Test #124.
''TONE-BD
555-233-143

Advertisement

Table of Contents
loading