Avaya S8700 Maintenance Manual page 1292

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
Port Audit and Update Test (#36)
This test sends port-level translation data from switch processor to the DS1
Interface circuit pack to assure that a trunk's translations are correct. Translation
updates include the following data: trunk type (in/out), dial type, timing
parameters, and signaling bits enabled. The port audit operation verifies the
consistency of the current state of trunk kept in the DS1 Interface circuit pack and
in switch software.
Table 8-230. Test #36 Port Audit and Update Test
Error
Test
Code
Result
Description / Recommendation
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
2000
ABORT
Response to the test request was not received within the allowable time period.
2100
ABORT
Could not allocate the necessary system resources to run this test.
FAIL
Test failed due to internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
PASS
Trunk translation has been updated successfully. The current trunk states kept
in the DS1 Interface circuit pack and switch software are consistent. If the
trunk is busied out, the test will not run but will return PASS. To verify that the
trunk is in-service:
1. Enter the status trunk command to verify that the trunk is in-service. If the
2. Enter the release trunk command to put the trunk back into in-service.
3. Retry the test command.
8-570
Issue 1 May 2002
trunk is in-service, no further action is necessary. If the trunk is
out-of-service, continue to step 2.
555-233-143

Advertisement

Table of Contents
loading

Table of Contents