Avaya S8700 Maintenance Manual page 1148

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
Table 8-173. Test #600 Congestion Query Test — Continued
Error
Test
Code
Result
Description / Recommendation
1, 2
FAIL
The buffer level is nearly exhausted.
FAIL
The C-LAN is congested, and no buffers are available.
1. Retry command at 1-minute intervals up to 5 times.
2. If command continues to fail, examine the C-LAN port measurements to
Low processor occupancy when C-LAN congested indicates circuit pack
failure.
1. If the problem persists, reset the circuit pack (reset board UUCSS).
2. If congestion recurs, replace the circuit pack.
High processor occupancy indicates the C-LAN is congested due to traffic load.
1. To relieve congestion in the short term, selectively busyout ports (busyout
2. To achieve a more permanent resolution, it may be necessary to move
3. Consider replacing affected C-LAN ports with new ports.
3
FAIL
The C-LAN circuit pack is not operating normally and is congested.
PASS
Hardware setting and attached cable type match C-LAN circuit pack
administration. The circuit pack detects no errors.
8-426
Issue 1 May 2002
determine what ports are heavily utilized and the processor occupancy of
the circuit pack.
port UUcSSpp) on the Control LAN circuit pack.
ports on this circuit pack to other Control LAN circuit packs.
Continued on next page
555-233-143

Advertisement

Table of Contents
loading

Table of Contents