EXP-INTF (Expansion Interface Circuit Pack)
Table 8-310. Test #589 Expansion Interface Packet Interface Test
Error
Test
Code
Result
Description / Recommendation
1033
ABORT
The test cannot run because the EI circuit pack does not have a fiber link
administered to it and there is not sufficient data to run the test or because EI
circuit packs on other port networks needed for this test are out of service.
1. Execute the list fiber-link command and determine whether the EI circuit
2. Follow procedures for applicable configuration:
DIRECT CONNECT
1. Issue the list config command for the cabinet and carrier where the
2. Run Test #237 and check for EXP-INTF circuit pack Error Type 1281 in the
555-233-143
pack under test is an endpoint of one of the administered fiber links. If so,
then proceed to step 2. If not, then this is considered to be a spare board,
and the test should not be attempted on this EI circuit pack.
neighbor EI circuit pack resides. If the results reveal that the board is not
recognized by software, the board is out of service because of this
condition. Perform the following steps:
a. If this test is being executed on an EI circuit pack located in the
PN, enter display errors and resolve any EXP-PN errors for the
port network where the neighbor EI circuit pack resides.
Re-execute this test.
b. If this test continues to abort with this abort code reset the DS1
CONV circuit pack (if so equipped) or the neighbor EI circuit
pack. This will not be destructive since the circuit pack cannot be
serving as the Expansion Archangel if it is not in service.
Error Log. If Error Type 1281 is present and/or Test #237 does not pass,
see repair procedures for Test #237, in
Table 8-303 on page
8-787.
Continued on next page
Issue 1 May 2002
8-811