ISDN-TRK (DS1 ISDN Trunk)
Table 8-391. Test #161 Loop-Around Test
Service State
out-of-service/NE
out-of-service/FE
pending-in-service,
pending-maint
maint-NE
maint-FE
in-service
1.
ISDN-TRK alarms; alarms against other objects may also be present.
555-233-143
1
Alarm
Possible Cause
Warning
Trunk is demand busied out.
Minor
NPE Crosstalk test (#6)
failed.
None
DS1 or UDS1 circuit pack
lost its signal.
Warning
Unadministered far end
Warning
The far-end trunk is busied
out.
None
Maintenance message was
sent and the switch is
waiting up to 2 min. for a
reply from the far end.
None
ISDN test call in progress
(test trunk long and test
isdn-testcall commands)
None
System link has been
busied out by command.
Warning
Signaling channel has been
down for over 90 sec.
Warning
Repeated failure of far end
to respond to messages.
Warning
The far-end trunk is being
tested.
None
Normal operating state
Possible Solution
Enter release trunk grp#/mbr#.
Replace DS1/UDS1 circuit pack.
Is the DS1/UDS1 circuit pack or
cable removed? Is the far-end
switch restarting? Check circuit
pack using procedures in
DS1-BD or UDS1-BD.
Administer corresponding trunk
on far-end switch.
Check the status of the far-end
switch.
Wait 2 minutes and check
service state after the pending
state has cleared.
Wait several minutes for test to
finish and check status again.
Check link status. Release link
with release link link#.
Consult ISDN-SGRP and/or
ISDN-LNK. Far-end signaling
channel may be busied out, or
the far-end switch may currently
be restarting.
Maintenance software will
periodically try to resend
messages. You can speed the
process with test trunk
grp#/mbr# and/or test
signaling-gr#.
Check status of the far-end
switch. Wait for testing to finish.
Continued on next page