ANN-BD (Announcement Circuit Pack)
e. Error Type 257
with this circuit pack. This error is not service-affecting and no action is
required.
f. Error Type 513
4352 to 4358, indicates the circuit pack has reported a hardware failure on
the circuit pack. The circuit pack should be replaced.
!
g. Error Type 1025
required.
h. Error Type 1281
memory locations in the speech main memory (SMM). Whenever this error
is logged, error 2817 will also be logged (Note j), causing maintenance to
run the Announcement Checksum test (#209) to determine whether the
bad memory location is used by an announcement.
i. Error Type 1538
exhibit one or more of the following symptoms:
1. The tests run on the ports of this circuit pack are returning with a
2. A busyout/release of the circuit pack has no affect on test results.
3. A list configuration command shows that the circuit pack and ports
The system will try to restore the circuit pack within 15 minutes. If the error
recurs after 15 minutes, then replace the circuit pack.
j. Error Type 2049 and 2817
Error Type 1281, Aux Data 17699 (Note h). Since that error means that a
defective speech memory location was found, the announcement
checksum error is also logged, causing the Announcement Checksum test
(#209) to run. This test determines whether the defective memory location
has corrupted any recorded announcements. If the Checksum test passes,
the faulty memory location is not currently being used; the Speech
Processor will then mark the location as faulty to prevent future
announcements from using it.
555-233-143
This error indicates transient communication problems
This error, when reported with Aux Data in the range of
CAUTION:
Replacing the circuit pack causes a loss of integrated announcements. Refer
to
''Essential Service Information'' on page 8-120
This error is not service-affecting and no action is
The Speech Processor (SP) found one or more faulty
The hyperactive circuit pack is out-of-service and may
NO-BOARD.
are properly installed.
NOTE:
As memory locations are marked faulty, the amount of available
memory decreases, lowering the amount of announcement time
available on the circuit pack.
of the AN-LN-PT MO.
These errors or logged in conjunction with
Issue 1 May 2002
8-125