CLSFY-PT (Call Classifier Port)
Tone Detection Verification Test (#42)
This test checks the operation of the TN744 in touch-tone receiver, call classifier
and R2-MFC modes. It verifies the circuit pack's ability to detect DTMF, ring back,
busy reorder and modem answer tones and to generate and detect forward and
backward MFC tones.
Table 8-176. Test #42 Tone Detection Verification Test
Error
Test
Code
Result
Description / Recommendation
none
ABORT
The system was not able to allocate every resource needed for this test, OR
there was an internal system error.
1
ABORT
The system could not allocate every resource needed to test the tones.
1001
ABORT
The system was unable to put the call classifier port in the appropriate mode to
test it.
1002
ABORT
The system could not allocate time slots for the test connection. This situation
could occur when the system is heavily loaded. If the system is not heavily
loaded, then test the TDM-BUS via the test tdm command.
1. Retry the command at 1-minute intervals up to 5 times.
1003
ABORT
The system could not allocate a Tone-Clock for the test connection. This may
be caused by a heavy load on the system or by a faulted Tone-Clock.
1. Check to see if there are any alarms against the Tone-Clock in the EPN
2. If a new Tone-Clock has been inserted, allow about 1-minute for
3. Retry the command at 1-minute intervals up to 5 times.
2000
ABORT
Call classifier circuit pack's response to the test request was not received
within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2006
ABORT
Indicates that the active Tone-Clock circuit pack or a Tone Detector circuit pack
may not be functioning properly.
1. Test the active Tone-Clock circuit pack in the EPN with the test tone-clock
2. Retry the command at 1-minute intervals up to 5 times.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
555-233-143
where the test aborted. If so, see
page 8-1659
and
''TONE-PT (Tone Generator)'' on page 8-1682
recommended procedures.
maintenance to run on the newly inserted circuit pack.
UUC command, and see
''TONE-BD (Tone-Clock Circuit)'' on page 8-1659
for failures.
''TONE-BD (Tone-Clock Circuit)'' on