Avaya S8700 Maintenance Manual page 1016

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
Figure 8-5 on page 8-217
2-part test, substituting "CES mode" for "PNC mode."
Table 8-129. ATM Board Framer Loop-Around Test (#1260)
Error
Test
Code
Result
Description / Recommendation
1002
ABORT
Time slots could not be allocated. Traffic could be heavy or time slots could be
out-of-service.
1. Run display errors, and perform repairs associated with TDM-BUS errors.
2. Retry the command up to 3 times at 1-minute intervals.
1003
ABORT
Tone receiver could not be allocated.
1. Run display errors, and perform the repairs associated with TTR-LEV and
2. Retry the command up to 3 times at 1-minute intervals.
1015
ABORT
ATM-TRK circuit pack not busied out
1. Busyout the ATM circuit pack.
2. Rerun the command.
1033
ABORT
ATM-TRK circuit pack not found
1. See if the switch can see the circuit pack. Run status trunk group.
2. Retry the command.
1139
ABORT
Major alarm on the EPN's packet bus
1. Run display alarms, and perform the repairs associated with PKT-BUS
2. Run display errors, and perform the repairs associated with PKT-BUS
3. Retry the command.
1141
ABORT
Packet-interface circuit pack out of service
1. See
1394
ABORT
ATM-TRK circuit pack out of service
1. Run the ATM Board Reset test (#1256).
2000
ABORT
Request timed out.
1. Retry the command up to 3 times at 1-minute intervals.
2060
ABORT
Packet-bus link has failed.
1. Retry the command up to 3 times at 1-minute intervals.
2. If the test continues to abort, run display errors, and perform the repairs
8-294
Issue 1 May 2002
and
Figure 8-6 on page 8-218
TONE-PT errors.
The test cannot run unless there is at least one Tone Detector available in
the EPN that holds the ATM-TRK circuit pack.
errors.
errors.
''PKT-INT (Packet
Interface)''.
associated with PKT-INT errors.
show a diagrams of this
Continued on next page
555-233-143

Advertisement

Table of Contents
loading

Table of Contents