Avaya S8700 Maintenance Manual page 834

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
Station Status and Translation Audits and
Updates Test (#36)
This test updates the analog port's message lamp state (if it has one) and
translations with information in the software.
Table 8-43. Test #36 Station Status and Translation Audits and Updates
Error
Test
Code
Result
Description / Recommendation
ABORT
Necessary system resources could not be allocated to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
1004
ABORT
A valid call seized the port during the test and aborted the test.
1. Use the display port UUCSSpp command to determine the station
2. Use the status station extension command to determine the service
3. If the port is active, wait until it is idle before testing. Retry the command at
4. If the test continues to abort, escalate the problem.
1005
ABORT
This test was aborted due to a configuration problem. The test is not applicable
for this type of analog port. This error can be ignored.
1006
ABORT
The port is out-of-service. The busy station extension command has been
given to this port, or it has been taken out-of-service by the failure of the NPE
Crosstalk test.
1. Look for error type 18 (port busied out) for this port. If this error is present,
2. Check for error type 1537 (NPE Crosstalk test failed) for this port. If this
3. Make sure that the terminal is connected and in service, and then retest.
2000
ABORT
Response to the test request was not received within the allowable time period.
2100
ABORT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
8-112
Issue 1 May 2002
extension.
state of the port.
1-minute intervals up to 5 times.
release the port (release station extension), and run the test again.
error is present, investigate the errors associated with the NPE Crosstalk
test (#6).
Continued on next page
555-233-143

Advertisement

Table of Contents
loading

Table of Contents