DID-DS1 (Direct Inward Dial Trunk)
Error Log Entries and Test to Clear Values
Table 8-204. DID-DS1 Trunk Error Log Entries
Error
Aux
Type
Data
Associated Test
1
0
0
Any
1 (a)
Any
15 (b)
Any
Port Audit and Update
test (#36)
18 (c)
130 (d)
None
257 (e)
57474
57473
513 (f)
57392
769 (g)
57393
1281
Conference Circuit test
(#7)
1537
NPE Crosstalk test
(#6)
1793 (h)
2305 (i)
50944
None
3840 (j)
Port Audit and Update
test (#36)
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test's description, and follow its recommended procedures.
2.
This alarm will only be raised when the System-Parameter Country form has the Base Tone Generator field
set to 4 (Italy). This alarm will be a MINOR alarm unless 75% or more trunks in this trunk group are out of service,
then the alarm will be upgraded to a MAJOR alarm.
3.
Major alarms may be downgraded to Warning alarms based on the value used in the set options command.
Notes:
a. Error Type 1—DS1 Interface circuit pack detects a hardware error on the
DS1 DID trunk. The Aux Data field indicates the following:
555-233-143
Alarm
Level
Any
WARNING
WARNING
MAJOR
MINOR
MAJOR
MINOR
MINOR
WARNING
MINOR
WARNING
MAJOR
MINOR
57476
On-hook before wink
57477
On-hook before ready to receive digits
57485
Wink too short for valid signal
On/Off
Board
Test to Clear Value
Any
test trunk grp#/mbr#
OFF
release trunk grp#/mbr#
ON
test trunk grp#/mbr#
2
2
ON
test trunk grp#/mbr# l r 4
3
ON
test trunk grp#/mbr# l r 3
3
test board UUCSS l
OFF
2