Avaya S8700 Maintenance Manual page 1439

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

DS1 CONV-BD
Failure Audit (#949)
This test is nondestructive.
This test queries the DS1 CONV circuit pack for any existing circuit pack or facility
failures and any unacknowledged cleared failure messages for auditing purposes.
Upon receiving the query request, DS1 CONV firmware sends failure reports to
the maintenance software for every error in its failure database.
This test operates on both MOs DS1C-BD and DS1-FAC. Error counts of both
MOs (DS1C-BD and DS1-FAC) that are displayed in the error log will be
incremented when this test is executed. This test is also executed internally by
the maintenance software when an alarm is resolved
Table 8-278. Test #949 Failure Audit
Error
Test
Code
Result
Description / Recommendation
2000
ABORT
Timed out while waiting for a response from the circuit pack.
2100
ABORT
Could not allocate the necessary system resources to run this test.
2300
ABORT
The downlink message necessary to run this test could not be sent.
2301
ABORT
The timer could not be set before sending the downlink message necessary to
run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2316
ABORT
Fiber link is not administered. Administer the DS1 CONV fiber link via the add
fiber-link command.
2500
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
FAIL
The DS1 CONV circuit pack reported failures or retransmitted a cleared failure
message.
1. Enter display errors and follow the associated repair procedures for any
PASS
The DS1 CONV circuit pack has no failures.
0
NO
The system software found no board.
BOARD
1. Reset the board.
2. Remotely retry the command.
555-233-143
DS1C-BD and DS1-FAC errors.
Issue 1 May 2002
8-717

Advertisement

Table of Contents
loading

Table of Contents