Maintenance-Object Repair Procedures
Hardware Error Log Entries and Test to Clear
Values
Table 8-33. 8-Port Analog Line Error Log Entries
Error
Aux
Type
Data
Associated Test
1
0
0
Any
1 (a)
40960
None
40977
40975
15 (b)
Any
Audits and Updates
test (#36)
18
0
busyout station
extension
130 (c)
None
257 (d)
Station Present test
(#48)
513
Battery Feed test
(#35)
769 (e)
Loop Around and
Conference test
(#47)
1025
NPE Crosstalk test
(#6)
1281 (f)
1793 (f)
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test's description, and follow its recommended procedures.
2.
Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the set options
command.
Notes:
a. These are in-line errors that can only be resolved over time.
Aux Data 40960 Indicates that too many simultaneous incoming ringing
attempts were made on this board. Only 4 ports on a board may ring
simultaneously. A 5
board.
Aux Data 40975 indicates that the terminal equipment was on-hook when
ring-tip was detected during ringing. This usually indicates a failure in the
terminal equipment or the type of terminal has a low ringer impedance.
8-82
Issue 1 May 2002
Alarm
On/Off
Level
Board
Any
Any
WARNING
OFF
WARNING
ON
WARNING
OFF
MINOR
ON
2
WARNING
MINOR
ON
2
WARNING
th
incoming call will cause an inline error from the
Test to Clear Value
test port UUCSSpp sh r 1
release station extension
test port UUCSSpp sh
test port UUCSSpp sh r 3
test port UUCSSpp sh r 2
test port UUCSSpp l r 3
test port UUCSSpp l r 3
555-233-143