Avaya S8700 Maintenance Manual page 1080

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
Table 8-152. BRI-SET/ASAI-ADJ Error Log Entries — Continued
Error
Aux
Associated
Type
Data
Test
3329
Any
Signaling Link
(k)
Status
(626)
3584
0,1
None
3585-
0
None
3839(i)
3840-
0
None
4095
(m) (n)
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test's description, and follow its recommended procedures.
2.
Major alarms on this MO may be downgraded to Warning alarms based on the value used in the set options
command.
Notes:
a. Errors of this type indicate violations of the ISDN-BRI signaling protocol;
timers associated with certain layer-3 messages have expired before a
required response was received. In the following table, the aux data field
indicates what timer has just expired. (For more information, refer to the
Avaya ISDN-BRI Specification.
8-358
Issue 1 May 2002
Alarm
Level
BBRI-SET
WARNING
Aux Data
Timer Type
2
First T303 (SETUP timer)
3
Second T303 (SETUP timer)
4
T305 (DISConnect timer)
5
First T308 (RELease timer)
6
Second T308 (RELease timer)
10
T316 (RESTart timer)
12
T309 (Layer-2 Failure timer)
16
TM100 (Management Information
message Timer 1)
17
TM200 (Management Information
message Timer 2)
102
TASAI (ASAI Routing timer)
ASAI-ADJ
ASAI-ADJ
ATT-ADJ
On/
LGATE-|AJ
Off
ATTE-AJ
Board
MAJOR/
OFF
2
WARNING
Continued on next page
Test to Clear Value
555-233-143

Advertisement

Table of Contents
loading