Maintenance-Object Repair Procedures
Port Audit Update Test (#36)
This test sends updates of the CO port translation for every translated port on the
circuit pack. The update is non-disruptive and guards against possible corruption
of translation data contained on the circuit pack. No response message is
expected from the circuit pack once it receives translation updates. The port
translation data includes: ground or loop start trunk, tone or rotary dialing trunk,
rotary dialing inter-digit timing, network balance R/RC, and disconnect timing.
Table 8-237. Test #36 Port Audit Update Test
Error
Test
Code
Result
Description / Recommendation
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABORT
Could not allocate the necessary system resources to run the test.
FAIL
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
PASS
This test passed. Translation information was successfully updated on the
circuit pack. User-reported troubles on this port should be investigated by
using other port tests and by examining trunk or external wiring. If the trunk is
busied out, the test does not run, but returns PASS. To verify that the trunk is
in-service:
1. Enter status-command to verify that the trunk is in-service. If the trunk is
2. Enter release-trunk command to put trunk back into in-service.
3. Retry the test command.
8-582
Issue 1 May 2002
in-service, no further action is necessary. If the trunk is out-of-service,
continue to step 2.
Continued on next page
555-233-143